Power over Ethernet (PoE) has been around now for several years, starting with Type 1 PoE (IEEE 802.3af) introduced in 2003 that delivers up to 15.4 W, with 13 W available for the device. That was followed by Type 2 PoE (sometimes referred to as PoE Plus) that delivers up to 30 W, with 25.5 W available for the device.
At these levels of DC power, no one ever really questioned the safety of PoE. But once four-pair Type 3 and type 4 PoE were introduced in 2018 at 60 W and 90 W respectively, and the National Electric Code was revised to address 60 W remote-powering circuits, many started to wonder if PoE is safe. We thought we’d take a closer look.
AC vs. DC
While blasting AC/DC’s “Back in Black” above 70 decibels is definitely NOT safe for your ears, there has long been the belief that DC power is safe while AC power is not. There’s some truth behind that as AC power is considered to be about 3 to 5 times more dangerous than DC—it takes far more milliamps of DC current than AC current at the same voltage to kill you. To better understand why, it helps to understand the difference between the two.
AC power alternates back and forth periodically while DC power flows in one direction. That’s why AC power has a frequency and DC power does not. In the U.S., AC power alternates 60 times per second (60 Hz). In Europe, it’s 50 times per second (50 Hz). An easy way to visualize the difference is to view them graphed—AC power makes a wave-like (sinusoid) pattern while DC is just a flat line.
When you are shocked by dangerous amperage levels of AC power, the alternating nature of AC power causes the heart to go into atrial fibrillation. The continuous flow of DC power is not as dangerous for the heart, but it can cause convulsive contraction and can even kill you at high enough levels. In addition to the level of current, the resistance of the body is also an important factor, which can be impacted by humidity, thickness of skin, weight, age and even sex. Dry skin has a greater resistance than wet skin and the amount of electrical current that flows through the body goes up when resistance goes down. And women are more susceptible to currents than men due to less overall body resistance.
In addition, the path makes a big difference. Electric shock only happens if there is a complete path with two contact points on the body for the current to enter and exit, and electricity will always take the easiest path to ground. The path the current takes has a lot to do with how harmful the shock is – a current that flows from hand to hand and therefore through your heart is far more dangerous than one that flows from, say, your finger to your elbow.
What Does that Mean for PoE?
Per IEEE standards, PoE is injected into a cable at voltage between 44 and 57V DC, typically 48V DC. Typically, anything less than 35V AC or 60V DC is considered safety extra low voltage (SELV), so by definition, PoE-enabled ports are SELV. That’s not to say that 48V DC can’t shock you (you’d know this if you ever touched your tongue to a 9-volt battery when you were a kid). And no one is recommending that you strip the insulation off of a twisted-pair cable conductor and poke it with your bare hands (especially while soaking wet).
But with PoE, you still have little chance of getting shocked from a disconnected cable due to the actual protocol itself. That’s because the power sourcing equipment (PSE) must experience a handshake with the powered device (PD) before any power is delivered. No handshake, no power. That’s quite different than an standard AC power receptable that is constantly supplying power, regardless of whether you’ve got a device plugged in.
In a nutshell, the answer is YES. PoE is safe.
There’s Always a But
So, if PoE is safe, why is it addressed in the NEC for power levels above 60 W? There is still the potential hazard caused by heat being generated by PoE within cable bundles that can cause insertion loss and cable degradation over time, preventing proper data transmission. And with everything from phones and security devices, to life safety systems connecting to and being powered over the network, a loss of signal can certainly become a life safety issue. That’s one reason why the NEC specifies the number of cables allowed in a bundle based on conductor size and temperature rating for 60W or higher PoE or requires the use of Limited Power (LP) cable.
There are ongoing discussions surrounding fire safety when it comes PoE. While it’s theoretically possible, it would take an absolute worst-case scenario—a large tight cable bundle all simultaneously delivering high-power 60W or higher PoE in a hot ceiling space (above 40°C) from one point to another without breaking out to smaller bundles/individual runs. It would also likely take low-quality unshielded cable construction (e.g., copper-clad aluminum) in close proximity to combustible material. Such a scenario can be avoided by following bundling guidelines and certifying (which will not pass CCA cabling).
It’s important to remember that even if there’s no danger, PoE can still wreak havoc on transmission if the cable isn’t properly balanced. In four-pair Type 3 and Type 4 PoE, power is delivered over all four pairs with data via common-mode voltage that splits the current between each conductor in the pairs. For this to happen, DC resistance must be balanced. Too much unbalance causes saturation of the transformer, which can cause Ethernet data signals to become distorted. That’s why we recommend testing for DC resistance unbalance using your DSX CableAnalyzer™ Series tester. Learn more about DC resistance unbalance testing here.
Learn more about the DSX CableAnalyzer
See the MicroScanner PoE
Recent Posts See All >
The Ultimate Guide to Network and Cable Testing
2024-03-13
Choosing Stranded vs. Solid Wire Cable
2024-03-06
Fluke CableIQ™ Qualification Tester vs. LinkIQ™ Cable+Network Tester
2023-06-13
What Is Return Loss?
2023-02-14
Three Reasons Cabling Certification Is More Important Than Ever
2023-01-05
Is cabling technician training (CCTT) certification worth it?
2022-11-25
More General Posts See All >
The Ultimate Guide to Network and Cable Testing
2024-03-13
Choosing Stranded vs. Solid Wire Cable
2024-03-06
How to Extend the Value of Your Versiv™ Investment
2023-12-21
What Is the Right Way to Test an MPTL?
2023-08-22
Contractors Say Skipping Certification Isn’t Worth the Risk
2023-07-06
Fluke CableIQ™ Qualification Tester vs. LinkIQ™ Cable+Network Tester
2023-06-13
Explore Our Products
MicroScanner™ Cable Verifier Series Learn More >
Versiv Kit Configurator
How will you be using your Versiv
Take a Tour
PRODUCTS
- Versiv
- LinkWare Live
- Cabling Certification
- Installation and Test
- Telecom Test
- Complete Product List
- Promotions
SUPPORT
- Downloads and Updates
- Knowledge Base
- Manuals
- Whitepapers
- Application Notes
- Warranty Information
- Contact Us
- Product registration
SOLUTIONS
- Solutions by Role
- Case Studies
- Fundamentals
COMMUNITY
- News
- Blog
- Social Media
- Certified Cabling Technician Training
- Online Training Videos
- Webinars
- Workshops
- Trade Shows
SALES INSIDER
- Integrity and Compliance Program
- Privacy Policy
- Terms of Use
- Sitemap
©2006-2021Fluke Corporation。保留所有权利。
RM2011, 20/F, SCITECH Tower, 22 Jianguomenwai Avenue, Chaoyang District, Beijing, China
地址:北京市朝阳区建国门外大街22号赛特大厦20层2011室
联系电话:400-8103435
沪ICP备11037028号-15
Chat withourFluke assistant
Welcome to Fluke's Chat GPT Assistant. As with othergenerative AI systems, this chatbot may occasionally generateincorrect information. For questions regarding the safe use of Fluketools, please refer to your owners manual. You must comply with youremployer’s safety standards and obtain necessary training before usingFluke tools or taking electrical measurements. To speak with a person,visit our Contact Us page.
How can I help you today?
"; // Clear local storage localStorage.removeItem('chatMessages'); localStorage.removeItem('chatId'); chatId = getOrGenerateChatId(); } // Observer for tracking changes in chat messages const chatMessagesElement = document.getElementById('chat-messages'); const observer = new MutationObserver(function (mutations) { mutations.forEach(function (mutation) { // Create local storage of chat messages TODO: This could probably be somewhere better but this works localStorage.setItem('chatMessages', chatMessagesElement.innerHTML); }); }); observer.observe(chatMessagesElement, { childList: true, subtree: true }); } });